Speedgoat IO33x-06

Speedgoat IO33x-06 — The Speedgoat IO33x-06 front plug-in

Library

  • >> speedgoatlib_hdlCoder_IO3xx

Description

This Speedgoat block performs the setup and configuration to use the Speedgoat I/O modules. To use this block, open the HDL Coder HDL Workflow Advisor and use it to generate a Simulink Real-Time interface subsystem. This block is located inside the generated Simulink Real-Time interface subsystem. The mask of this block controls the block parameters. Do not edit the parameters directly. The FPGA I/O module block descriptions are for information purposes only. The relevant parameters are promoted to the top level of the generated Simulink Real-Time interface mask.

The IO33x-06 I/O module provides 16 simultaneous 16-bit 500 kHz A/D channels with an analog input range of ±10.24 V, ±5.12 V, ±2.56 V or ±1.28 V.

Ports

This driver block has no input or output ports.

Parameters

FPGA Module Identifier - Unique identifier for FPGA I/O module

1 (default) | n

Enter a unique number. This setting must match the setting of the corresponding design under test (DUT) subsystem generated. This is usually only relevant in a multi-module model, as otherwise the default value 1 is applied. The module identifier ordinal sequence will also correspond to the ordinal sequence of the modules' positions on the PCIe bus. In this way such modules of the same device type can be uniquely identified. For this reason, if multiple modules of the same type are installed in the target machine and one module is not in use within a given model, a bus and slot for the modules which should be used must be specified.

Range - for better accuracy, small voltages can be amplified

±10.24 volts (default) | ±5.12 volts | ±2.56 volts | ±1.28 volts

This parameter is used to indicate the expected input voltage range and is promoted to the top level of the generated Simulink Real-Time interface mask.

Target Screen Output

This block does not produce any output on the target machine display.