Skip to main content

Customer Login

This content is for Speedgoat customer only. Log in to see content.

Forgot your password?

Don't have a Speedgoat account? Create an account.

Documentation
CONTENTS

Speedgoat IO397 A/D Setup

Speedgoat IO397 A/D Setup — The Speedgoat IO397 A/D setup settings

Library

  • >> speedgoatlib_hdlCoder_IO3xx

Description

This Speedgoat block performs the setup and configuration to use the Speedgoat I/O modules. To use this block, open the HDL Coder HDL Workflow Advisor and use it to generate a Simulink Real-Time interface subsystem. This block is located inside the generated Simulink Real-Time interface subsystem. The mask of this block controls the block parameters. Do not edit the parameters directly. The FPGA I/O module block descriptions are for information purposes only. The relevant parameters are promoted to the top level of the generated Simulink Real-Time interface mask.

Ports

This driver block has no input or output ports.

Parameters

FPGA Module Identifier - Unique identifier for FPGA I/O module

1 (default) | n

Enter a unique number. This setting must match the setting of the corresponding design under test (DUT) subsystem generated. This is usually only relevant in a multi-module model, as otherwise the default value 1 is applied. The module identifier ordinal sequence will also correspond to the ordinal sequence of the modules' positions on the PCIe bus. In this way such modules of the same device type can be uniquely identified. For this reason, if multiple modules of the same type are installed in the target machine and one module is not in use within a given model, a bus and slot for the modules which should be used must be specified.

FPGA Board Type - defines the I/O module

IO397-50k

Select the correct I/O module.

Range A/D Channel 1 - A/D input range

+5.12V | +10V | +10.24V | ±5V | ±5.12V | ±10V (default) | ±10.24V

The absolute input voltage limit for the analog inputs is ±11 V relative to ground for each pin. This parameter is promoted to the top level of the generated Simulink Real-Time interface mask.

Target Screen Output